COMPASS for Pressure Calibration Software Download/Upgrade


Request a quote

TITLE VER USE WITH DOCUMENTS
COMPASS®
for Pressure™
5.0.50
2018.11.01
FPG8601, PG7000, PPC2, PPC2+, PPC2 AF, PPC3, PPC4, PPCH, PPCK, PPCK+, RPM3, RPM4, 7050, 7052, 7250, 7252, 7350, 7615, 7750, 7010, 7215, 2465, 2456
Third party piston gauges, pressure controllers and T&M hardware.
Example Setup Database »
A COMPASS example greatly simplifies the requirements of adding a new device to the COMPASS.

Application Notes »
Product web page »

Description
When downloaded, this file can be run to install COMPASS for Pressure Basic and COMPASS for Pressure Enhanced.
Summary
COMPASS® for Pressure is a universal platform for all of your pressure calibration software needs. From piston gauges calibrating individual devices in the cal lab to transfer standards characterizing racks of sensors in production, COMPASS provides an off-the-shelf software tool to maximize the automation of your calibration and testing processes.

COMPASS for Pressure integrates calibration functions with pressure specific dependencies that are missing from more generic software packages. Thanks to COMPASS's flexible data output options, the data it collects is easily imported into higher level applications such as Fluke MET/CAL®. This allows the benefits of COMPASS's specialization in pressure calibration to be enjoyed while maintaining the link to your organization's overall calibration management system.

Updates Include:
5.0.50 (2018.11.01)
FIX CPP-42 Help file, improved description for hold limit in pre-test tab
CHANGE CPP-49 Help file, update PG7000 run window
FIX CPP-50 "Medium" during test initialization now changes 7615 setting
CHANGE CPP-51 Help file, improved Ruska PC and mass set import instructions
CHANGE CPP-52 Help file, Improved CalTool for PG7000 information
CHANGE CPP-77 Improved Safety Limits for Autodetect 6270A
FIX CPP-93 Autodetect 6270A recognizes BG measurement modules
FIX CPP-94 Networked database recognizes multi-user license
FIX CPP-98 Hold limit for "% DUT FS" was calculated based on "% DUT Span"
FIX CPP-99 Leak Test feature always stopped test
FIX CPP-100 Plot/graph selection was not retained test to test
FIX CPP-102 During leak test status bar showed "Dwell Time Remaining"
FIX CPP-111 Get Command macros only ran once
FIX CPP-113 Exercise max target FIXed in test "PMM Cal Sled Test BG200K -15 to 30 psiG Diff"
CHANGE CPP-114 Macros improved for PM200 cal sled calibrations
ADD CPP-115 Add Fluke Calibration 2638A DAQ Support Device to database
ADD CPP Add Fluke Calibration 8270A/8370A as Autodetect Device
5.0.25 (2016.05.13)
ADD CPP-74 The Fluke 2271A is now supported by the Auto-Detect setup function within COMPASS. The instrument can be used as a DUT, Reference and/or to measure the output of an analog or HART DUT connected to the front panel of the instrument.
ADD CPP-62 Manual piston gauges will now use a pressure resolution that is one digit more than the resolution of the active DUT. Changing the Pressure Resolution selection on the Piston Gauge calculator will now cause data to be logged in the selected resolution when running a manual test. Note that the resolution active when the data file is created is used until a new data file is created.
ADD CPP-3 An example setup for the Mensor CPC6000 is now available in the default database.
ADD CPP-73 The serial number of the active PMM is logged in the data file when a Fluke 2271A or 6270A is used as the test pressure reference. The value is available for reports in both the External Serial Number 1,2 fields of the device header and in the Reference Operation column logged for each point in the data file.
ADD CPP-54 A new test macro that provides ISO17025 compliant uncertainty calculations is available in the default database. The macro can be used in an existing Test Definition by ensuring first that the test is setup as an Advanced Test, then selecting the macro "UncCalc" as the Test Event Macro. In [Tools][Options][Data in File] ensure that the columns User Defined 1,2 and string Data 1 are selected for logging to the data file. See the UncCalc test macro for additional details.
CHANGE CPP-83 The front panel pressure unit of legacy Ruska controllers, the Fluke 6270A and the Fluke 2271A will automatically change to inHg when a test is executed in inHg. Previously, the controllers would remain in their current unit of measure and COMPASS would convert and display the pressure in inHg.
FIX CPP-85 Commands sent in a Macro with the ioSendCommand function would never actually be sent to the instrument. The issue is now resolved.
FIX CPP-69 The 2456 PG monitor would not properly updated ambient pressure, temperature and humidity. This issue is now resolved.
FIX CPP-72 The 6270A will no longer generate a front panel error message when setting ATM test points in a pressure exercise or a Test Definition.
FIX CPP-77 The upper and lower limit settings of the 6270A are updated based on the range requirements of the selected DUT and/or Test Definition.
FIX CPP-68 The COMPASS Database Data Viewer can now consistently import and export *.dat files. Previously there were cases in which some files could not be imported or exported properly.
FIX CPP-82 Viewing the Setup picture associated with a Test Definition during Test Initialization would close COMPASS if the picture file type is PNG or a UNC path is selected. An appropriate warning message now displays and incompatible paths and file types are restricted from being used in the Test Definition.
FIX CPP-71 When editing a Test Definition, the Rt-Click option to add an ATM point in the pressure exercise would generate a run-time error in COMPASS. This issue is now resolved and ATM points are fully supported in the pressure exercise.
FIX CPP-44 Using an RPM4 as the ambient pressure source with a Ruska 2465 or 2456 would generate a run time error in COMPASS. This issue is now resolved.
FIX CPP-76 COMPASS 5.0 did not properly support binary RS232 communication. This prevented HART communications from functioning properly. The issue is now resolved.
FIX CPP-75 When creating a set command the label next to the list of set application types now displays "Apply Set".
FIX CPP-59 Resolved a misspelling in the Tools menu.
4.2 (2012.07.27)
ADD CP-1334 COMPASS for Pressure now supports the calibration functions of CalTool for RPTs. This functionality allows users to fully adjust and report calibration results for supported Fluke products. Sample tests are included with COMPASS that support automated collection of as received data and as left data with an adjustment in between. Review the CalTool for RPTs application note for details. The COMPASS CalTool implementation supports the following instruments: PPC2+, PPC2AF, PPCK+, PPCH, PPCH-G, PPC3, PPC4, PPC4E,RPM3, RPM4, E-DWT, molbox1, molbox1+, and molbox RFM. When Demo versions of COMPASS for Pressure expire, COMPASS will function but limit activity to the calibration of supported Fluke products.
ADD CP-1338 The installation of COMPASS 4.2 supports the export of data into MET/TRACK 8.X. A separate downloadable patch was created to support the export of data into MET/TRACK 7.3. MET/CAL 7.3 users must download and apply the patch to support the COMPASS to MET/TRACK data export.
ADD CP-1303 A new [Data][Show Calibration Coefficients] menu choice was added to read and display the active RPT calibration coefficients. This menu option is part of the CalTool support and only applies to the following products: PPC2+, PPC2AF, PPCK+, PPCH, PPCH-G, PPC3, PPC4, PPC4E,RPM3, RPM4, E-DWT, molbox1, molbox1+, and molbox RFM.
ADD CP-1226 There are two new report templates used to adjust calibration coefficients for supported products run using the new CalTool features.
ADD CP-1224 Application Note on how to calibrate RPTs with COMPASS for Pressure
FIX CP-1176 When using Windows 7 or Windows Vista, there may be large delays polling the output of instruments.  The problem was exaggerated when using a multiplexer as part of the data acquisition.  The problems did not occur on older operating systems.  The problem is now resolved by using a new COMPASS Remote Interface tool (DHIIO.exe).
FIX CP-1337 Fixed the example setup for Ruska 2455 in default.mdb.
FIX CP-1335 The 2465 Autofloat prompt window to "Open bell jar to vent" was unavailable behind the COMPASS Test Complete dialog when completing tests in absolute mode.  As a result, the vacuum pump would not properly shut down at the end of a test.  The dialog no longer displays at the end of the test and the vacuum pump is shut down without a prompt.
FIX CP-1327 The molbox "Upstream Pressure" or "Downstream Pressure" selected as DUT in the test would display incorrectly when repeating a test.  The last used molbox output now displays correctly between repeated tests. 
FIX CP-1306 Checking "Use remote options" from the [Database][Remote Options] menu would incorrectly overwrite the options in the remote configuration file.  The function now works as documented.  The settings in the remote file are now used locally. 
FIX CP-1305 There was difficulty entering data in the ambient fields of the PG Calculator.  The cursor went back to the beginning of the field after entering any number. This behavior happened only during test not when using the PG Calculator from the [Tools] menu.  The problem is now resolved
FIX CP-1296 An ATM point in a test definition could generate an incorrect warning message when initializing a test.  The warning indicated that the test defined pressure exceeded the limits of the active controller.  The warning no longer displays incorrectly. 
FIX CP-1281 During test initialization, the Head Medium would be empty when loading the FPG. Now the field will show the active head medium that is selected in FPG Tools.
FIX CP-1209 The Ruska 7615 was not automatically set to Gauge measurement mode during test initialization.  The issue is now resolved.  The 7615 is now properly initialized for a test regardless of its current state.
FIX CP-1336 The test pressure would time out without getting ready if an ATM point was used as the first pressure point of a test that used a non-autodetect controller that was setup to use Ready commands.  The problem is now resolved by ensuring that the Ready commands are polled whenever a vent command is issued.  
FIX CP-1181 The lower limit of a  Ruska 7250 was not properly set during test initialization.  This could cause the test error message: "error 502 - low limit exceeded".  The lower limit is not set correctly.
4.1 (2012.02.17)
ADD CP-1112 The Ruska 7252 controller is now supported in a combined test port configuration. This allows a target pressure to auto select the proper channel and set the test pressure. Previously this configuration was not supported.
ADD CP-1122 MET/TRACK reference devices now include environmental monitors, 100011 - Ambient Pressure, 100012 - Ambient Temperature and 100013 - Ambient Humidity.  These devices are now imported as standards along with te COMPASS calibration data.
ADD CP-1144 Additional examples are now included in the default database (default.mdb). The examples are automatically added to the current COMPASS setup database upon upgrade when the [Database], [Setup] menu, Auto update examples option is enabled in COMPASS.
ADD CP-1205 To bypass the 500 limit on the MET/TRACK asset selector, place a file called AssetLimit.dat into c:\. Specify the new limit inside the file, blank for no limit.  The 500 limit exists to improve performance of asset selection on large databases.  The list is auto refined based on manufacturer, model and serial number information entered for the specific device.
ADD CP-1242 The export prompt file entry allows overriding values exported from COMPASS. The DEFAULT entry in the prompt file line is used to populate the field in MET/BASE.
FIX CP-1110 Specific models of Ruska controllers would set and control zero gauge instead of venting the system pressure.
FIX CP-1111 The Ruska controller run time display did not always indicate the unit of measure selected in COMPASS. Now the test defined unit of measure always displays on the Ruska run time display.
FIX CP-1114 A Ruska controller venting test pressure could incorrectly indicate a "Ready" state prior to completing the vent process.
FIX CP-1117 During Test Initialization, an extra "B" displayed in the range text for a PPC or RPM4 configured to use a BG range RPT.
FIX CP-1118 Setting pressure on Ruska controller would show "Out of Range" after changing units from psi to kPa for devices with two channels such as 7052,7252 and 7750.
FIX CP-1119 Seat-based license could not be added or upgraded from version before 4.0 in some regional settings of Europe.
FIX CP-1120 The asset calibration Due Date was calculated by COMPASS when test data was exported to MET/TRACK. The Due date is now based on Asset fields I4228, I4229 and the cal date. It is not exported from COMPASS.
FIX CP-1121 Out of tolerance (T) was only recognized by the export to MET/TRACK when not comingled with other status flags.
FIX CP-1126 During test initialization, "Customize Output" would not show for Fluke 700 module, which is desired by customers. Now COMPASS allows all devices other than non-DHI PG to customize output during test initialization.
FIX CP-1137 Ruska 7215 came up with autodetect option but would not run. No 7215 is added to the list of supported AutoDetect device.
FIX CP-1139 Ruska 7252i would not change units other than psi.
FIX CP-1208 Fixed an issue where required fields without defaults would prevent the export to MET/TRACK from completing.
FIX CP-1149 Ruska controller resolution will be preserved in COMPASS now.
FIX CP-1150 Could not change unit during test initialization for Ruska 7010
FIX CP-1154 May receive unhandled exception error when sorting MET/TRACK asset grid in COMPASS during Test Initialization.
FIX CP-1155 The MET/TRACK Asset selection screen no longer displays the "mtag" value.
FIX CP-1159 2465A would show ready instantly after COMPASS step "waiting for stability" in absolute mode.
FIX CP-1160 The hold and stability limits shown on FPG run scheen were divided by 1000 from what were on [Pressure][Set] tab of COMPASS, which would cause the wrong indication of ready status. Now these limits are consistent.
FIX CP-1162 The first negative gauge mode target pressure entry for a Piston Gauge would result in zero for the mass to be loaded.  All subsequent negative gauge pressure points would select the correct masses.  The issue is now resolved
FIX CP-1165 Default Mass Loading Resolution in Tools/Options would not be enforced on PG Calculator. Now the Mass Loading Resolution in Tools/Options and on PG Calculator are consistent.
FIX CP-1172 Data file header information, including model and serial number, were not properly updated when using a Ruska 2465A.
FIX CP-1177 "Clean up" database option in the  [Database Maintenance Tool] could sometimes fail with invalid password error message.  The issue is now resolved.
FIX CP-1178 The mode of Ruska controllers such as the 7250 is now changed to "Measure" at the beginning of a test.  Previously if the controller were in a vent state, a user was required to manually change the mode in order to user the controller as a DUT.
FIX CP-1184 During test initialization, Head Medium would show blank for PPCs. Now the field will show the head medium that is selected on the PPC front panel.
FIX CP-1192 The example setups in Default.mdb would not get automatically imported to the active setup database.
FIX CP-1193 "Over Flow" error would show when importing certain Ruska .ms files into COMPASS. The problem has been fixed by examining the file for legatimacy before importing.
FIX CP-1194 Letter designated "mass ID" values from Ruska .ms files could not be imported into COMPASS.  Now COMPASS supports "mass ID" values with both numbers and letters.
FIX CP-1201 Could not run Negative Gauge mode for Ruska 2456 PG Monitor. Now "Negative Gauge" mode shows in mode selection during test initialization.
FIX CP-1209 Ruska 7615 could not be set to gauge mode
FIX CP-1245 When MET/TRACK export is active in Tools, Options, MET/TRACK; Asset information entered into COMPASS was required to be entered in the same case as listed in MET/TRACK. Failure to use the same case would prevent the test initialization from completing.
FIX CP-1246 Asset selection dialog may return wrong record after resorting the grid by clicking on the column header.
4.00.22 (2011.08.19)
ADD(CP-776) A new [Tools][Repair Template Macros] option was created in the Report Editor. The menu is available only when editing an existing template. Use the item to map macros in a template to corresponding macros in a new database. The macros must already exist. Please review the Help in the Report Editor for additional details.
ADD(CP-788) New COMPASS profile for Ruska 2456-LEM environmental monitor.
ADD(CP-819) The PPC4E is now supported via the Auto Detect setup option.
ADD(CP-837) The comparison and device output displays now include resize controls.  Displayed values can be resized with the slider on the right-hand-side of the form, or via the keyboard, using SHIFT <> (or up and down). The font can be set to bold/normal, by right-clicking on the slider or via CTRL-B
ADD(CP-854) Several new example devices were added to the default database. 
ADD(CP-877) Support Ruska controllers and monitors as auto-detected devices.  All 7000 series controllers and models are supported.  Note that the System Controllers are excluded and must be setup with direct remote commands.
ADD(CP-890) Ruska piston gauge features are now supported in COMPASS. An import from WinPrompt option was added to the [Tools] menu.
ADD(CP-903) DHI and Ruska piston gauges include a graphical indicator for piston position and rotation. 
ADD(CP-912) New COMPASS profile for Ruska 2465-Autofloat.
ADD(CP-915%) Added seat-based license scheme that allows user to purchase specified number of seats and to add additional seats into existing COMPASS license
ADD(CP-958) All device setups in COMPASS support the selection of a MET/TRACK asset. All non DUT assets are now used as standards for the DUT.
ADD(CP-974) Pressure media used by WinPrompt and PressCal are included as default media selections.
ADD(CP-978) Intermediate calculation results are now visible within the PG Calculator
ADD(CP-980) "Vent Head" correction was added to support resevoir head corrections in a piston gauge.
ADD(CP-982) New piston gauge mass loading resolutions of 5mg, 20mg and 50mg were created.
ADD(CP-994) COMPASS Export to MET/BASE now supports prompting for additional values to be entered on-the-fly, during the import, for the Inventory and Calibration tables. The feature is driven by and configured via the file compassexport.prm in the C \DHI\COMPASS for Pressure directory. Review the help file for additional details.
ADD(CP-997) Added option to support 2nd fluid medium for non-autodetect piston gauges
ADD(CP-1009) Various units of measure are now supported for the characteristics that define a piston cylinder, a mass set and a mass bell. 
ADD(CP-1043) Support "Negative Gauge" mode for non-autodetect piston gauges.
ADD(CP-1107) A new Tip of the Day feature was added.  Enable and disable the tips by using the [Help] menu in COMPASS.
ADD(UMC-7) Custom units created in the Unit of Measure converter are now stored in the database. 
CHG(UMC-11) Ruska unit of measure conversions are applied win "inH2O" based units are selected.  DHI unit of measure conversions are applied with "inWa" based units are used.  Refer to the Unit of Measure help to see the difference between the conversions.
CHG(CP-831) The flashing edit indicator is now yellow when creating a new record while editing an existing record flashes red. This applies to DUTs, Test Definitions, Support Devices and all editors within COMPASS.
CHG(CP-815%) Reference Raw Output #1 is included as a data header by default on new installations of COMPASS. Existing users that upgrade are not affected.
CHG(CP-962) Revised COMPASS export to MET/BASE. Supports creation of (up to 7) Standards (links) and has optional prompts.
CHG(CP-973) The piston gauge calculator now simultaneously displays both the pressure resolution and the mass loading resolution.  Previously it was one value or the other. 
CHG(CP-987) COMPASS setup database is now encrypted and cannot be directly accessed from MS Access without a password.  
CHG(CP-1012) The "Constant Offset" field on the Tolerance tab of the Piston-Cylinder Editor was removed.  
CHG(CP-1020) Use Fluke Calibration in product description and logo
CHG(CP-1051) The installation program now present an option to store the database in a non default location. 
CHG(CP-1061) COMPASS Export to MET/TRACK now uses imp2.exe and reports progress & messages during the export.
FIX(CP-55X) Strip charts properly scroll and resize based on the source data.
FIX(CP-792) Print report to PDF file created a seperate file for each page.
FIX(CP-794) Changing printers in the Report Editor did not take affect unles the Report Editor is restarted.
FIX(CP-795) ATM is used as the pressure exercise min point when 0 is defined as the min exercise point in the Test Definition and an automated piston gauge is used as the pressure reference in absolute by ATM mode.
FIX(CP-806) A PG7000/PG9000 used as a raw source instrument would always default to Absolute measurement mode during test initialization. The active measurement mode on the front panel of the PG is now used.
FIX(CP-807) During test initialization an incorrect DUT or Reference instrument out of range error message could occur during test initialization. The error message now displays only when the device range is less than the test defined range.
FIX(CP-811) All AMH masses are loaded whenever a PPC will be used to exercise the system pressure when the PG is the reference.
FIX(CP-818) Macro Editor now scans for and reports on duplicate function names upon save.
FIX(CP-840) Enhanced error message for COMPASS Export to MET/BASE in regards to inventory recall interval and unit.
FIX(CP-841) Selections on the Tools, Options, MET/TRACK tab were not properly retained when edits to other options were made or when COMPASS is opened or closed.
FIX(CP-851) Assets added in MET/TRACK within a COMPASS session might not be available for selection until COMPASS is restarted.
FIX(CP-853) Support COMPASS data file with comma as decimal separator for exporting to MET/BASE.
FIX(CP-868) COMPASS Export to MET/BASE would attempt to calculate cal due date, rather than export the value from COMPASS
FIX(CP-887) The Piston Gauge Calculator doesn't support zero psi as a target pressure.
FIX(CP-933) "Include mass bell in minimum PG pressure option" was not functioning properly in all cases.
FIX(CP-971) The serial number of Hart instruments as read by command 14 was incorrect whenever the last byte of the serial number had a value less than 16. The issue is now resolved.
FIX(CP-972) PG Calculator form size shrinked if the mass list was selected before closing the form in the last section.
FIX(CP-977) The DUT tolerance was not properly calculated when a test definition is run in a specific unit of measure that was not the same as the DUTs unit of measure. Tests run in %DUTSpan functioned correctly.
FIX(CP-983) Cannot display multiple strip charts on readings of third party PG for which "Auto Detect" is not checked.
FIX(CP-990) Set point logged for "MIN" point with PG as controller shows random number even though the pressure target sent to PG is correct.
FIX(CP-1015) When exporting data to MET/TRACK C215%1 may be populated with an odd combination of semicolons and NULL
FIX(CP-1016) Incorrect upper / lower limits shown on v7 cal report for data exported from COMPASS.
FIX(CP-1019) COMPASS units are preserved, with the exception of those which have the milli (m), mega (M) or kilo (k) prefix - which is split off. Now also supports kA, mPa and MV.
FIX(CP-1021) The Load Settings option in the test initialization would fail when the model included additional model descriptors. For example "PPC4" would work, but "PPC4 A1000/A100" would fail.
FIX(CP-1038) Removed obsolete online reference from new macro header
FIX(CP-1053) The Process Gas Editor did not properly support the comma as a decimal separator.
FIX(CP-1058) A template macro that is no longer available to a report template is listed as "Missing Macro" instead of a blank line in the Template Macro selection dialog. The macro could be part of a different database or it may have been deleted by the user.
FIX(CP-1060) The last file path of a Report Template is used as the default file path when opening a Report Template.
FIX(CP-1101) A piston gauge platform with a reference vacuum device would fail to initialize in gauge mode if a prior test were run in gauge mode.
   
3.00.43 (SP1) (2011.02.11)
ADD(CP-802) Support PG7000 and PG9000 models that respond with FLUKE as the manufacturer.
CHG(CP-793) An automated PG7000/PG9000 system with a PPC and AMH will use ATM as the minimum pressure when exercising in a test that is run in Absolute by ATM.
3.00.42 (SP1) (2010.07.07)
ADD(CP-689) Support alternate units of measure and temperature references for the Piston Cylinder effective area.
ADD(CP-775) Added new instruments to the default database.
CHG(CP-786) When [Tools][Feature Options Display]<\ Support Temperature\> is disabled, use the DUT temperature device unit of measure to log temperature data. When the feature is enabled, the temperature unit selected during test initialization defines the unit of measure for the DUT temperature device.
CHG(CP-785) The Final Output Label of a device is displayed on the manual entry dialog to assist in the entering of manual data.
CHG(CP-781) ATM is a supported target for the pressure exercise min or max targets. Click the label next to the field to insert an ATM point.
CHG(CP-766) The build information in addition to the Major and Minor revisions is displayed on the Splash screen during program initialization.
CHG(CP-753) Font size is limited on device run screens to prevent fonts that are too large or small.
CHG(CP-708) [Help][About] dialog uses the new "Fluke- DH Instruments" logo.
CHG(CP-691) A device is now considered "in tolerance" if the error is equal to the tolerance. Previously, a device was "out of tolerance" when the error was equal to the tolerance.
CHG(CP-159) When a macro changes the SN or ID of a device it should also be changed on the various device displays.
CHG(CP-155) Additional COMPASS specific fields are exported to MET/TRACK. See Help file for complete set of fields that are mapped.
CHG(CP-657) The number of test cycle points can be changed from a macro.
CHG(CP-751) When the Data File Name selection in [Tools][Options][Data File] is set to secondary SN, the device serial number is used when the selection does not apply.
FIX(CP-784) Might encounter "Syntax error near '0'" when exporting test data file to MET/TRACK.
FIX(CP-783) Status field logged in the data file does not always update with status codes.
FIX(CP-779) The measurement mode of a profile DUT is not recalled between tests.
FIX(CP-778) Incorrect reference temperature values logged during automated test with an FPG reference.
FIX(CP-762) Export to MET/TRACK, data file resolution was not maintained.
FIX(CP-761) Export to MET/TRACK, option
FIX(CP-760) Removed redundant error messages associated with data files that cannot be exported to MET/TRACK.
FIX(CP-759) A macro run at the end of a test cycle can result in duplicate points made available to a test macro. Data file information is now synchronized prior to calling any test event macros at the end of a test cycle to avoid this problem.
FIX(CP-756) The COMPASS Ready option in a Test Definition would fail to return Ready if the reference and controller used different units of measure.
FIX(CP-755) Output resolution of DHI devices does not always conform to the front panel when the "...Preserve front panel resolution.." option is selected.
FIX(CP-754) Interface macros had a maximum limit of 4 calls per second regardless of the device defined poll interval value.
FIX(CP-752) The label associated with values that are manually entered during a tests were not always correct. In particular, when the raw output type and the final output type were different. For example, Ohms and Temperature.
FIX(CP-747) Target pressure on a PPC could have excessive resolution. The target is now limited to the resolution of the device.
FIX(CP-744) Exporting a COMPASS data file to the Test Data Database might fail if no device information is present in the data record.
FIX(CP-735) Line pressure and temperature fields display on final test initialization step even when the options are disabled.v FIX(CP-719) An error message would display when creating a user defined device when the Output Relationship was set to "Same". The error indicated that a unit must be selected from a drop down list when in fact the list was empty.
FIX(CP-709) Data viewer now shows only relevant columns on the Data grid, with the appropriate column headings.
FIX(CP-703) Effective area unit conversion was performed with limited resolution. This impacted the final area determination which resulted in a faulty piston gauge pressure output.
FIX(CP-695) BSL linearity calculation was incorrect.
FIX(CP-693) If a test point is removed by a macro and the test definition has multiple cycles of line pressure or temperature, the test would loop indefinitely.
FIX(CP-157) Shared command macro information was not exported to external databases using the Database Maintenance Tool.
FIX(CP-659) The Piston Gauge Platform editor displays "PC/MS" tab 2 times. The second tab should display "Sources" instead.
FIX(CP-653) Newly created Mass Bells are not listed in the Piston gauge Editor Mass Bell list.
FIX(CP-650) The True Mass label on the Mass Set Editor is missing. The field displays "kg" only.
FIX(CP-644) Controller list for line pressure includes 2 "Manual Entry" choices.

  • Inicio
  • Productos
    • Novedades de Fluke Calibration
    • Calibración eléctrica
      • Estándares eléctricos
      • Calibradores
      • Multímetros de banco
      • Software de calibración eléctrica
    • Calibración de radiofrecuencia
      • Fuentes de referencia de radiofrecuencia
      • Accesorios de calibración de radiofrecuencia
      • Software de calibración de radiofrecuencia
    • Equipo de adquisición de datos y pruebas
      • Multímetros de banco
      • Adquisición de datos
      • Software de Adquisición de Datos
    • Calibración de temperatura
      • Patrones principales
        • Celdas de punto fijo de ITS-90
        • Termómetros de resistencia de platino estándar (SPRT)
        • Aparatos de mantenimiento
        • Calibradores de comparación de nitrógeno líquido
        • Puentes de resistencia
        • Resistencias estándares
      • Baños de calibración
        • Baños de calibración compacta
        • Baños de calibración estándar
        • Baños de aplicación especial
        • Accesorios para baños de calibración
        • Controladores del baño de calibración
        • Fluidos de baños de calibración
      • Calibradores de temperatura industriales
        • Calibradores de metrología de campo de bloque seco
        • Calibradores de metrología de bloque seco
        • Calibradores de pozo seco de mano
        • Calibradores de bloque seco en terreno
        • Microbaños
        • Calibradores infrarrojos
        • Hornos de termopar
        • Pozo seco de bloque doble
        • Pozo seco de punto cero
      • Sondas/Sensores
        • Termómetros de resistencia de platino (PRT)
        • Termistores
        • Termopares
      • Indicadores de temperatura
      • Calibradores multifunción
      • Software de calibración de temperatura
    • Calibración de humedad
      • Generadores de humedad
      • Registradores de datos de humedad y monitores
    • Calibración de presión
      • Manómetros de pistón
        • Calibradores de pistones NMI
        • Calibradores de pistones completos
        • Calibradores de pistones neumáticos de alta presión
        • Manómetros de pistón hidráulicos
        • Accesorios del calibrador de pistón
      • Controladores/Calibradores
        • Calibradores/Controladores de presión baja
        • Calibradores y controladores de presión neumática
        • Calibradores y controladores de gas neumáticos de alta presión
        • Calibradores y controladores hidráulicos
      • Monitores de presión
        • Monitores de presión baja
        • Manómetros digitales
        • Monitores de presión de referencia
      • Balanzas de pesos muertos
        • Balanzas de peso muerto neumático
        • Balanzas de peso muerto de aceite
        • Balanzas de peso muerto de agua
        • Balanzas de peso muerto hidráulico de alta presión
        • Accesorios de balanzas de peso muerto
      • Monitores y calibradores manuales
        • Calibradores de presión
        • Control de presión neumática
        • Bombas y comparadores de presión hidráulica
      • Handheld Pressure Calibrators
      • Calibración de datos de aire
      • Monitores ambientales
      • Accesorios de calibración de presión
      • Sistemas personalizados de calibración de presión
      • Software de calibración de presión
    • Calibración de flujo
      • Estándares de flujo de gases
      • Accesorios de flujo de gases
      • Estándar de flujo gravimétrico principal GFS
      • Software de calibración de flujo
    • Calibradores de procesos
      • Calibradores de temperatura
        • Calibradores de temperatura portátiles
        • Calibradores de bloque seco y micro-baños
        • Termómetros digitales de precisión
        • Sondas de temperatura
        • Calibradores infrarrojos
        • Termohigrómetro con registro de datos
      • Calibradores de presión
        • Calibradores de presión digitales
        • Calibradores de presión portátiles
        • Balanzas de pesos muertos
        • Manómetros digitales de precisión
        • Bombas manuales para calibración
      • Calibradores multifunción
      • Calibradores de lazo mA
      • Software de calibración de procesos
    • Software de calibración
      • Software MET/CAL
      • Soporte MET/CAL
      • Software de administración de activos
      • Software de calibración de temperatura
      • Software de calibración de presión
      • Software de calibración de flujo
      • Software de calibración mecánica/dimensional
    • Servicio y soporte técnico
    • Todos los instrumentos de calibración
  • Comprar
    • Dónde comprar
    • Solicitar una cotización
    • Solicitar una demostración
    • Solicitar una Consulta de Venta
    • Certified Pre-Owned Equipment
    • General Services Administration (GSA)
    • Financing Program
    • National Stock Numbers (NSNs)
    • Payment Options and Tax Info
  • Novedades
    • Comunicados de prensa
    • Promociones
    • Vínculos de la industria
    • Metrology Salary Survey
  • Capacitación y eventos
    • Conferencias y Exposiciones
    • Cursos de formación (in USA)
    • User Group Meetings
    • Seminarios Web
      • Seminarios en línea
      • On-Demand Seminars
  • Literatura y educación
    • Education Hub
    • About Calibration
    • Artículos y educación
    • Literatura sobre productos
    • Manuales de productos (guías de usuario)
    • Demostraciones virtuales y vídeos
    • Blog
  • Soporte Técnico
    • Service Request (RMA)
    • Programas de servicio
    • Servicio técnico
    • Base de Conocimientos
    • Acreditaciones
    • Centros de servicio autorizados
    • Calibration Certificates
    • Community Forum
    • My MET/SUPPORT
      • Activate
      • Procedures
      • Software
      • Technical Bulletins
      • Priority Support
      • Manuals
    • Manuales de productos (guías de usuario)
    • Hojas de datos sobre la seguridad (SDS)
    • Safety, Service, and Product Notices
    • Descargas de software
  • Sobre Nosotros
    • Contacto
    • Visítenos
    • Empleo
    • Fluke Calibration
      • Calibración de temperatura de Hart Scientific
      • Calibración de presión y flujo de DH Instruments
      • Calibración de presión de Pressurements
      • Calibración de presión de Ruska
    • Empresas Fluke
    • Integridad y cumplimiento
    • Preguntas que se hacen frecuentemente
    • ¿Por qué elegir Fluke Calibration?
Inicio|Literatura|Descargas de software|Software|COMPASS for Pressure Calibration Software Download/Upgrade
©1995-2023 Fluke Corporation
             

Secondary menu

  • Disclaimer
  • Declaración de privacidad
  • Terms of Use
  • Términos y Condiciones